DFT+U: Difference between revisions

From Wiki
Jump to navigation Jump to search
Maxgarcia (talk | contribs)
No edit summary
Maxgarcia (talk | contribs)
No edit summary
Line 23: Line 23:
'''IMPORTANT NOTES:'''
'''IMPORTANT NOTES:'''


*In ''VASP'' there are several ''DFT + U'' approaches that can be used. You can specify the one you want by setting the corresponding value in the flag ''LDAUTYPE'' = "value". The default approach in ''VASP'' is the one introduced by Dudarev et al. (''LDAUTYPE ='' 2).[http://prb.aps.org/abstract/PRB/v57/i3/p1505_1] For further details see ''VASP'' manual.[http://cms.mpi.univie.ac.at/vasp/vasp/On_site_Coulomb_interaction_L_S_DA_U.html]
*In ''VASP'' there are several ''DFT + U'' approaches that can be used. You can specify the one you want by setting the corresponding value in the flag ''LDAUTYPE'' = "value". The default approach in ''VASP'' is the one introduced by Dudarev et al. (''LDAUTYPE ='' 2).[http://prb.aps.org/abstract/PRB/v57/i3/p1505_1] For further details on this flag see ''VASP'' manual.[http://cms.mpi.univie.ac.at/vasp/vasp/On_site_Coulomb_interaction_L_S_DA_U.html]


*The values in ''LDAUL'', ''LDAUU'' and ''LDAUJ'' must be specified for all atomic species!
*The values in ''LDAUL'', ''LDAUU'' and ''LDAUJ'' must be specified for all atomic species!


*It is not meaningful to compare the total energies resulting from calculations with different ''U'' and/or ''J'' (c.q. ''Ueff = U - J'' in case of Dudarev's approach).
*It is not meaningful to compare the total energies resulting from calculations with different ''U'' and/or ''J'' (c.q. ''Ueff = U - J'' in case of Dudarev's approach).

Revision as of 13:49, 25 October 2012

go back to Main Page, Núria López and Group, Computational Resources, Chemistry & More, Group Pages


UNDER CONSTRUCTION...


To perform a DFT + U calculation using VASP you just have to add the following flags to your INCAR file:


GGA = PW | PB | LM | 91 | PE | RP | PS | AM → The value of this flag depens on the DFT functional you want to use)[1]

LDAU = .TRUE.

LDAUL = "value" → It specifies the l-quantum number for which the on-site interaction is added (1 = p ; 2 = d ; 3 = f).

LDAUU = "value" → It specifies the effective on-site Coulomb interaction parameters (U).

LDAUJ = "value" → It specifies the effective on-site Exchange interaction parameters (J).

LASPH = .TRUE. → VASP recommends to add this flag to the INCAR file when using gradient corrected functionals.


IMPORTANT NOTES:

  • In VASP there are several DFT + U approaches that can be used. You can specify the one you want by setting the corresponding value in the flag LDAUTYPE = "value". The default approach in VASP is the one introduced by Dudarev et al. (LDAUTYPE = 2).[2] For further details on this flag see VASP manual.[3]
  • The values in LDAUL, LDAUU and LDAUJ must be specified for all atomic species!
  • It is not meaningful to compare the total energies resulting from calculations with different U and/or J (c.q. Ueff = U - J in case of Dudarev's approach).