G09: Difference between revisions
Jump to navigation
Jump to search
| Line 18: | Line 18: | ||
* [[Solvation models, Polarizable Continuum Model (PCM)]] | * [[Solvation models, Polarizable Continuum Model (PCM)]] | ||
* [[Tests on solvation energies, PCM in G03 and G09 and SMD]] | |||
Revision as of 11:30, 13 January 2010
go back to Main Page, Computational Resources, Chemistry & More, Computational Codes, GAUSSIAN
Solvent Effects
As with Gaussian03, the SCRF keyword requests that a calculation be performed in the presence of a solvent by placing the solute in a cavity within the solvent reaction field.
- The integral equation formalism variant IEFPCM, is the default SCRF method. It has not changed from Gaussian03, BUT the formalism used and its implementation has changed. That is: you will get different results in G03 and G09, using the same method.
- The default RADII used in G03 was UAO , whilst now is UFF with spheres placed by default on all Hydrogen atoms. No need to use the SPHEREONH= keyword, except if you use UAO or another radii model that does not have them explicitly.
- It seems to give no "convergence failure" problems, but maybe its too early to say so.