Solvent Effects

As with Gaussian03, the SCRF keyword requests that a calculation be performed in the presence of a solvent by placing the solute in a cavity within the solvent reaction field.

  • The integral equation formalism variant IEFPCM, is the default SCRF method. It has not changed from Gaussian03, BUT the formalism used and its implementation has changed. That is: you will get different results in G03 and G09, using the same method.
  • The default RADII used in G03 was UAO , whilst now is UFF with spheres placed by default on all Hydrogen atoms. No need to use the SPHEREONH= keyword, except if you use UAO or another radii model that does not have them explicitly.
  • It seems to give no "convergence failure" problems, but maybe its too early to say so.
  • It is able to perform frequency calculations in solvent, giving enthalpies, free energies, ZPE corrections...

Gaussian09 vs Gaussian03